DRAG DROP -
Your customer plans to use HPE OneView for VMware vCenter to deploy ESXi system. They created a server profile template that they want to use in HPE OneView.
Put the steps required to configure HPE OneView for VMware vCenter Server on the left into their correct order on the right.
Answer :
Your customer wants to add dedicated Fibre Channel connectivity to the HPE Synergy frame running HPE Synergy 480 Gen10 compute modules, each with one CPU socket populated. Currently they use two 12 Gb SAS switches and two HPE Virtual Connect SE 100Gb F32 Modules for HPE Synergy installed in third fabric.
What must be done to enable dedicated FC connectivity for this HPE Synergy frame?
Answer : C
Your customer plans to deploy ESXi systems to HPE Synergy and HPE ProLiant servers using HPE OneView for VMware vCenter Server.
Which statement about HPE OneView for VMware vCenter Server functionality is true for this environment?
Answer : C
What is a limitation when creating a server profile?
Answer : A
What is a restriction of using a RoCE network?
Answer : A
You configured a vVol datastore using HPE Storage Integration Pack for VMware vCenter.
Which storage object should you check using SSMC to verify whether vVol datastore is configured properly?
Answer : D
Your customer plans to use HPE Primera to boot HPE Synergy compute nodes. They currently have two HPE Virtual Connect SE 100Gb F32 Module for Synergy modules installed in the frame. The customer wants to use FC as a storage access protocol.
What must be done to complete this task?
Answer : A
Which compute node parameters are captured within server hardware type?
Answer : C
Your customer wants to add a second HPE Synergy frame to an existing logical enclosure based on a single HPE Synergy frame. The customer wants to use a highly available master setup.
Which procedures should be performed during the expansion process? (Choose two.)
Answer : BE
Your customer needs to move an application from an HPE Synergy 480 Gen10 Compute Module to an HPE Synergy 660 Gen10 Compute Module. The 480 has a switch that has been manually zoned outside of HPE OneView.
What must the customer do before migrating the application?
Answer : A
Your customer reports that they cannot deploy HPE Synergy compute nodes using HPE OneView for VMware vCenter Server (HPE OV4VC).
What should you check during troubleshooting process?
Answer : B
You are troubleshooting an HPE OneView server profile that presents a critical state. The server profile was configured with a Link Aggregation Group.
What should you check to fix the issue?
Answer : B
Your customer has an HPE Synergy frame equipped with a D3940 Storage Module. Each of the compute nodes has an appropriate storage controller installed and two 12Gb SAS switches installed in the first fabric.
The customer reports that compute nodes cannot access the storage module.
What should you verify first when troubleshooting this problem?
Answer : D
Your customer added a new Ethernet network in HPE OneView that is used to manage their HPE Synergy platform.
When the customer tries to connect one of the compute nodes to this network through the server profile, this network is not available.
What must be done to fix this issue?
Answer : B
HOTSPOT -
Click the option that will allow you to change the ESXi image used in an OS Deployment Plan.
Answer :
Have any questions or issues ? Please dont hesitate to contact us