HPE Compute Solutions v1.0

Page:    1 / 4   
Exam contains 57 questions

DRAG DROP -
Your customer plans to use HPE OneView for VMware vCenter to deploy ESXi system. They created a server profile template that they want to use in HPE OneView.
Put the steps required to configure HPE OneView for VMware vCenter Server on the left into their correct order on the right.



Answer :

Your customer wants to add dedicated Fibre Channel connectivity to the HPE Synergy frame running HPE Synergy 480 Gen10 compute modules, each with one CPU socket populated. Currently they use two 12 Gb SAS switches and two HPE Virtual Connect SE 100Gb F32 Modules for HPE Synergy installed in third fabric.
What must be done to enable dedicated FC connectivity for this HPE Synergy frame?

  • A. SAS switches must be moved to second fabric and FC modules installed in the first one.
  • B. For VC-FC modules, all of server facing ports must be properly licensed.
  • C. For Brocade switches, a logical interconnect group must be created in HPE OneView.
  • D. A second CPU must be installed for all HPE Synergy 480 Gen10 compute nodes.


Answer : C

Your customer plans to deploy ESXi systems to HPE Synergy and HPE ProLiant servers using HPE OneView for VMware vCenter Server.
Which statement about HPE OneView for VMware vCenter Server functionality is true for this environment?

  • A. HPE Synergy requires HPE Composer 2 for full functionality of HPE OneView for VMware vCenter Server.
  • B. Individual systems can be added the HPE OneView for VMware vCenter Server through an iLO management processor.
  • C. Only systems managed using HPE OneView can use HPE OneView for VMware vCenter Server functionalities.
  • D. HPE ProLiant servers need an HPE OneView for VMware vCenter Server license for full functionality.


Answer : C

What is a limitation when creating a server profile?

  • A. BIOS settings can be changed only when UEFI optimized is selected as boot mode.
  • B. It is not possible to create shared volumes on demand through a server profile.
  • C. iLO management is limited to the integration with Active Directory or LDAP.
  • D. Administrator cannot define more than 8 connections within a server profile.


Answer : A

What is a restriction of using a RoCE network?

  • A. It is by default configured as an untagged network and cannot be a part of a network set.
  • B. It is not supported with HPE Virtual Connect SE 40 Gb F8 Module for HPE Synergy.
  • C. It does not support smart link and private network features.
  • D. It does not support Private VLAN and Multicast VLAN.


Answer : A

You configured a vVol datastore using HPE Storage Integration Pack for VMware vCenter.
Which storage object should you check using SSMC to verify whether vVol datastore is configured properly?

  • A. Virtual Volume Set
  • B. Virtual Volume
  • C. App Volume Set
  • D. Storage Container


Answer : D

Your customer plans to use HPE Primera to boot HPE Synergy compute nodes. They currently have two HPE Virtual Connect SE 100Gb F32 Module for Synergy modules installed in the frame. The customer wants to use FC as a storage access protocol.
What must be done to complete this task?

  • A. Add FC upgrade licenses in HPE OneView that will enable FC connectivity for the modules.
  • B. Enter both modules into a maintenance mode, then enable FC connectivity through CLI.
  • C. FC connectivity on the modules should be enabled through the service console by disabling FCoE.
  • D. Enable FC primary and secondary boot on the modules through the HPE OneView interface.


Answer : A

Which compute node parameters are captured within server hardware type?

  • A. Size of the memory installed
  • B. Number of the CPUs
  • C. Mezzanine card configuration
  • D. Installed operating system


Answer : C

Your customer wants to add a second HPE Synergy frame to an existing logical enclosure based on a single HPE Synergy frame. The customer wants to use a highly available master setup.
Which procedures should be performed during the expansion process? (Choose two.)

  • A. Create a new logical enclosure based on both HPE Synergy frames.
  • B. Move one of the master modules to the appropriate interconnect bay in the second frame.
  • C. Re-parent an existing enclosure group to the new logical interconnect group.
  • D. Create a new logical interconnect group and enclosure group for two frames setup.
  • E. Modify an existing logical interconnect to include second HPE Synergy frame.


Answer : BE

Your customer needs to move an application from an HPE Synergy 480 Gen10 Compute Module to an HPE Synergy 660 Gen10 Compute Module. The 480 has a switch that has been manually zoned outside of HPE OneView.
What must the customer do before migrating the application?

  • A. Create a new server profile template and apply to the new hardware.
  • B. Edit the server profile and change server hardware type.
  • C. Migrate the application to a Logical JBOD and connect it to the new server.
  • D. Copy the server profile and assign the clone to the new hardware.


Answer : A

Your customer reports that they cannot deploy HPE Synergy compute nodes using HPE OneView for VMware vCenter Server (HPE OV4VC).
What should you check during troubleshooting process?

  • A. If all compute nodes are added to the vCenter Server.
  • B. If HPE OneView credentials are added in vCenter Server.
  • C. If vCenter Server is licensed in the HPE OneView interface.
  • D. If the HPE OneView instance is integrated with HPE OV4VC.


Answer : B

You are troubleshooting an HPE OneView server profile that presents a critical state. The server profile was configured with a Link Aggregation Group.
What should you check to fix the issue?

  • A. If both FlexNICs are connected to different networks.
  • B. If both FlexNICs are configured with the same speed.
  • C. If the logical enclosure is built on at least three HPE Synergy frames.
  • D. If the logical enclosure is configured with redundant master modules.


Answer : B

Your customer has an HPE Synergy frame equipped with a D3940 Storage Module. Each of the compute nodes has an appropriate storage controller installed and two 12Gb SAS switches installed in the first fabric.
The customer reports that compute nodes cannot access the storage module.
What should you verify first when troubleshooting this problem?

  • A. If the D3940 module is imported in managed state that allows volume provisioning.
  • B. If the D3940 storage module is properly licensed through HPE OneView interface.
  • C. If there is at least one iSCSI network configured that will provide access to the module.
  • D. If there is a logical interconnect created based on the 12Gb SAS switches.


Answer : D

Your customer added a new Ethernet network in HPE OneView that is used to manage their HPE Synergy platform.
When the customer tries to connect one of the compute nodes to this network through the server profile, this network is not available.
What must be done to fix this issue?

  • A. Check within the server profile which server hardware is used, and perform the Refresh operation on this compute node to get the latest adapter information.
  • B. The newly created network must be added to the uplink set within the LIG, and Logical Interconnect configuration must be updated from the LIG.
  • C. Check the Logical Enclosure settings and verify if the maximum number of networks allowed for this LE is reached.
  • D. To make this network available to use in the server profile, the customer must enable the Smart Link feature within network definition.


Answer : B

HOTSPOT -
Click the option that will allow you to change the ESXi image used in an OS Deployment Plan.



Answer :

Page:    1 / 4   
Exam contains 57 questions

Talk to us!


Have any questions or issues ? Please dont hesitate to contact us

Certlibrary.com is owned by MBS Tech Limited: Room 1905 Nam Wo Hong Building, 148 Wing Lok Street, Sheung Wan, Hong Kong. Company registration number: 2310926
Certlibrary doesn't offer Real Microsoft Exam Questions. Certlibrary Materials do not contain actual questions and answers from Cisco's Certification Exams.
CFA Institute does not endorse, promote or warrant the accuracy or quality of Certlibrary. CFA® and Chartered Financial Analyst® are registered trademarks owned by CFA Institute.
Terms & Conditions | Privacy Policy